Alcomate
AL6000P Prestige Professional
Breathalyzer
Newest
Technology, User Replaceable Calibration Module, Highest Accuracy,
Commercial Grade,
Digital Alcohol Detector

Professional model from Sentech Technologies.
quantitative conversion of breath
alcohol content to equivalent blood alcohol (BAC) percentage within seconds.
Results displayed on a large LED panel. Self-diagnostic menu
alerts/prompts on display. User Replaceable Sensor module allows onsite
re-calibration when required. Reusable one way flow mouthpieces. U.S. Department of Transportation (DOT) and
NTHSA approved. Reliable, precision accuracy.
Automatic sample volume sensor with visual and audio error messaging. Auto power shut off.
Completely portable unit. Suggested for personal,
institutional and law enforcement field use.
Supplied with extra mouthpieces and soft carry case.
|

|
Now Features...

User Replaceable
Sensor Module
Instant Onsite
Re-Calibration
No need for outside
Re-Calibration Services |
|
PRINCIPLE
DOT/NTHSA Approved
Meets US Coast Guard Requirements
CE Mark, NF Mark
ISO Certified
Test Count &
Re-calibration Notification
Flow Pressure Sensor
Pressure Sensing/Error Detection |
The Alcomate AL6000P Prestige Professional alcohol breath
analyzer is the latest high
technology U.S. DOT and NTHSA approved alcohol
detection instrument employing the newest
Sentech semi-conductive microchip oxide sensor to determine equivalent blood alcohol content within a range of
0.00% to
0.40% in increments of
.01% from a measured breath sample with a sensor accuracy rate of +/-
0.01% at 0.10% BAC. Results are displayed digitally within a
few seconds. Fast, easy, and convenient to use,
this professional portable model is
recommended for both personal and law enforcement field use when high
performance and accuracy of results is indicated. The AL6000P Prestige Professional
incorporates the newest oxide gas sensor from Sentech, one of the largest
manufacturers of microchip sensors worldwide. The
AL6000P model includes 5 specially designed non-disposable one-way mouthpieces
that prevent subject manipulation of breath sampling by "blow back" and insuring
proper breath sampling. Easy to replace sensor module eliminates the
inconvenience, added costs and service interruption of outside re-calibration
services. Simply install a new sensor module after the recommended 6-8 month use
(dependent on light to heavy use) or when unit consistently displays suspect or
unexpected results. Replacement sensor modules sold separately. As with all
electronic measuring devices, accurate results are significantly impacted by
failure to follow proper testing protocol and use instructions included with the
unit. Specifications and features of the AlcoScan AL6000P Prestige Digital
Pro model follows:
 |
*MEMS is the
abbreviation for Microelectro-Mechanical Systems, a technology developed at the
University of California at Berkley that employs miniscule silicon sensors or
"motes" a.k.a "Smart Dust". Smart Dust, as the name implies, is the equivalent
of coating a receptor microchip with micro fine powder consisting of millions of
individual smart sensor motes. The use of MEMS, or smart dust, exponentially
increases the sensitivity and detection effectiveness of the receptor microchip
in identifying and quantifying targeted molecules (hydrocarbons in the case of
alcohol breath analyzers). This increased sensitivity and accuracy however can
be more readily compromised by cigarette smoke or other contaminates in the air.
Therefore it is extremely important that MEMS devices be used as free from
ambient smoke as possible.
See
Technology and Accuracy.
|
 |
DOT Approved. Accuracy Certified to DOT, NHTSA Standards.
User replaceable re-calibration sensor module.
Sensor Accuracy: +/- 0.01% at 0.10% BAC
0.00%
to 0.40% Blood Alcohol Equivalent in 0.01% increments.
Advanced Semiconductor Microchip
Oxide Sensor.
Automatic Sample Volume Flow Sensor with Error Prompt
Large 3 digit
LED Numeric Display.
Power on Self
Test, self Calibration, Audible and Visual Ready Prompt.
Displays Test results in
5-8 Seconds.
Test Recycle time
<
forty five
(45) Seconds.
Built
in 16 bit A/D Converter Microchip.
Standby
Mode and Auto Power Off.
Low
Battery Alarm and Visual Indicator.
Power Supply:
Two AA 1.5V batteries (included).
Approximately
200 Test Cycles Between Battery Change
(3 hours continuous).
Weight:
105 grams, 3.7
ounces.
Dimensions: 166X59X27 mm
Recommended use: Personal, field law enforcement, institutional
1 year Manufacturers Warranty |
TESTING PROTOCOL
Important. Wait at least 10 minutes after
consuming alcohol or smoking before testing. This period is necessary for all
the alcohol molecules to be absorbed into the system preventing a high false
positive reading. Also, components of tobacco smoke can effect the accuracy of
BAC readings by interfering with the sensor microchip. It is also recommended to
perform the test in a smoke free environment. See
Technology and Accuracy.
1. Depress the power button to activate the
test unit. The unit is powered by two AA alkaline 1.5V batteries (included).
2. Place one of the five mouthpieces (included) into the breath sample intake
port.
3. The Alcomate AL6000P Prestige will automatically begin a self test and sensor
calibration routine. The digital display will commence a numeric countdown
sequence indicating that purge cycles and circuit tests are taking place. A RDY (ready) indicator on the display and 0 in the display
result panel indicate the unit is ready for breath sampling.
4. Take a deep breath and blow steadily and continuously for 2-3 seconds into
the mouthpiece or until two short beeps are heard. Note: Intermittent
blowing or blowing too long or too short will result in an "Flu" or
error message on the display.
Press the "Power" button to restart the test routine from the
beginning.
5. After 5-8 seconds, the test result in percentage
BAC will be displayed indicating completion of the test.
6. The AL6000P Prestige will then power off automatically after 10 seconds.
 |
Using the Alcomate AL6000P Prestige is an
professional and accurate way to avoid the many risks
associated with alcohol consumption. These risks are well publicized and can
lead to life threatening consequences not only for intoxicated individual but
also for other persons potentially affected by the
condition. Used as a monitor, the
Alcomate AL6000P Digital can indicate when equivalent blood alcohol
percentages are below or above state legal limits preventing potential arrest or
worse, reckless endangerment of others. This professional breath analyzer is recommended for "on the spot" testing whenever alcohol consumption
is planned or intoxication is suspected. With the exception of replacement of
the batteries, the Alcomate AL6000P Prestige should provide accurate readings indefinitely as long
as the sensor is not damaged. Test protocol and use
instructions must be followed for accurate results.
For additional information on technology method and specificity expectation see
Technology and Accuracy. |

Deluxe Field Case |
USER RE-CALIBRATION MODULE
The
AL6000P Prestige features a user replaceable re-calibration sensor module. Easy to
replace sensor module eliminates the
inconvenience,
added costs and service interruption of outside recalibration services. Simply
install a new sensor module after the recommended 6-8 month use (dependent on
light to heavy use) or when unit consistently displays suspect or unexpected
results. Replacement sensor modules sold separately. See the
Instructions for
sensor replacement.
AVAILABILITY
Each Alcomate AL6000P Prestige Professional Digital
Breath Analyzer comes boxed with five (5) reusable, non-disposable one-way mouthpieces, zippered deluxe field case, carry strap, two AA 1.5 volt batteries and
complete operating instructions. For
sanitary reasons, it is recommended that each mouthpiece be used only by the
same person or be
washed in hot water or sterilized between uses. Note: The special mouthpiece must
be used for each test or damage could occur to the sensor microchip. Mouthpieces
are constructed of high grade ABS plastic and will last indefinitely.
Re-calibration sensors are available separately. Sensor modules come with
complete installation instructions.
Description
|
Packaging
|
Sale Unit
|
Cost
|
Order
|
Alcomate AL6000P Prestige Digital Pro Breath Analyzer
|
Boxed
|
One
(1) Unit
|
$129.00
|
 |
|
|
Three
(3) Units
|
$360.00
|
 |
|
|
Six
(6) Units
|
$630.00
|

|
|
|
Twelve (12) Units
|
$1,140.00 |
 |
|
|
Twenty Four (24) Units |
$1,920.00 |
 |
Alcomate AL6000P Prestige
GREEN Calibration Sensor Module Only*
|
Boxed |
One (1)
Unit |
DISC |
 |
Alcomate AL6000P Prestige
RED Calibration Sensor Module Only*
|
Boxed |
One (1)
Unit |
$25.00 |
 |
Alcomate AL6000P Prestige One
Way Mouthpieces Only
|
Poly |
100 Each Pack |
$39.00 |
 |
|
|
1000 Each Pack |
$350.00 |
 |
*IMPORTANT NOTE:
If you purchased your AL6000 Prestige before
October 2007, please select the GREEN
sensor when replacing. If you purchased your AL6000
Prestige after December 2007, please select the
RED sensor when replacing.
If you purchased your AL6000 Prestige between
October - December 2007, you must verify whether
you have a RED or GREEN sensor module. This can be done by examining the
sensor module's circuit board color through the rear air vent on top of the
device.
*
Note: This sensor
will only fit the new AL6000P Prestige model. It will not
fit older models of the AL6000 breathalyzer. The breathalyzer unit must be
marked Alcomate "PRESTIGE" Model.
For bulk purchases of
Fifty (50) units or more please contact us by e-mail
Customer Service
See the
Instructions for
sensor replacement


|